Skip navigation

Armfield Engineering Education

Armfield limited engineering education equipment HEAT AND MASS TRANSFER UNIT OPERATIONS

UOP10 Laboratory Steam Generator - Issue 7

As many laboratories do not incorporate a centralised or reliable steam source, Armfield offers an advanced boiler providing a constant supply of steam. The compact unit requires only connection to water and electrical supplies for operation.

ORDERING SPECIFICATION

‚ A floor standing continuous steam generator.
‚ Splash proof electrical enclosure and switches.
‚ Solid state level control on feed water tank.
‚ Easy and safe access for maintenance and inspection, with door isolator to the main electrical enclosure.
‚ Manufactured in accordance with Module G of the European Pressure Equipment directive 97/23/EEC.
‚ An instruction manual is included in the supply.

Description

The Armfield UOP10 Laboratory Steam Generator comprises a mains fed header tank with level control which supplies the pressure vessel via a quiet running, heavy duty, high pressure feed pump.

The pressure vessel is built to all relevant British and European standards. Being heavily insulated with two totally immersed Incaloy heating elements it provides a highly efficient and economical means of generating a continuous supply of steam.

The two heating elements are individually switched and the unit will operate satisfactorily on a single element.

The integral control panel houses an on/off mains switch with switchable test functions, LEDs display the operational status of the equipment.

The UOP10 is fully safeguarded via MCBs and an RCD (residual current device) to give a long trouble free life.

The components of the UOP10 are mounted within a steel cabinet finished with a high gloss stove enamel paint for corrosion resistance and long life. Front panels are hinged for easy access and are fitted with key operated handles.

It is recommended that for optimum life of the unit, feedwater should be demineralised.

Optional Accessory

In some countries it is illegal to blow down a steam boiler directly into the drainage system and a separator must be used. Armfield can offer a purpose built separator to fulfill this function. Users should check local regulations on the requirements for this unit.

UOP10-10: Blow Down Separator

Technical Details

Steam output at 100°C: 55kg/hr (continuous)
Heat output: 36kW
No. of heating elements: 2
Max. operating pressure: 10 bar

Requirements

Electrical supply:

UOP10-C: 415V/3ph/50Hz
UOP10-D: 208V/3ph/60Hz
UOP10-E: 380V/3ph/50Hz
UOP10-F: 220v/3ph/60hz

Water supply:

1.0l/min @ 2 bar maximum usage

Shipping specification

Volume: 2.1m3
Gross weight: 490kg

Overall dimensions

Height: 1.93m
Width: 0.68m
Depth: 1.12m

Note: Total height of 2.5m is required for access


Extended 2 year Warranty
on all Armfield Products

DATA SHEET

PRODUCT CATEGORY:
Engineering Education