WATER TREATMENT PROCESSESAnaerobic treatment processes involve bacteria which function only in the absence of air. These processes are becoming more popular in the water treatment industry as they have considerable advantages over aerobic processes, including low sludge production, tolerance of stop/start operation, production of a useful fuel (methane) and relatively high throughput.
The Armfield Anaerobic Digester is designed as a bench top training facility and as a means of providing operational process data for plant design purposes.
• A bench top Anaerobic digestic for waste water treatment studies
• Equipped with two 5 litre packed bed, upward flow reactors
• Each reactor has gas sampling & collection facilities
• Reactors may be operated in series or parallel flow arrangement, using
variable speed peristaltic pumps
• Feed flow rate to each reactor can be accurately & independantly
controlled to any temperature between ambient and 55°C, using 200W
heating jackets
• Thermostatic cut-out set to 85°C
• An instruction manual describing test and practical work capabilities,
including details of a proven test substrate formulation is included
> effluent treatability studies, including solids, carbon and biogas
balances to determine purification (COD-BOD)
> determining optimum operating temperatures, feed rates and ratios
> observing effect of pH and influent nutrient concentration
> process stability studies
> determination of controlling kinetics
> 100% scale-up to industrial requirement
> preparation, warming and acclimation of a anaerobic reactor
> demonstration of the multistage nature of anaerobic digestion
> undertaking carbon balances
> studying effects on purification performance of:
• hydraulic loading
• feed ratios
• temperature
• nutrient deficiency
• influent
The anaerobic digester comprises two 5 litre upward-flow packed bed reactors with feed rate and temperature control facilities to allow steady, continuous operation at up to seven litres per day over periods of many days.
The reactors may be operated in series or parallel. A buffer vessel between the reactors permits discharge of excess flow from the first reactor when the second reactor is operated in series but at a lower flow rate. The flow rates to the vessels are set and controlled by calibrated peristaltic pumps.
The temperature of each reactor is controlled by an electric heating mat wrapped around the external wall. The temperture distribution within each reactor is maintained to ±0.5°C. Reactor temperatures may be separately set at any desired value in the range ambient to 55°C.
The gas off-take from each reactor is taken to a volumetrically calibrated collector vessel operating by water displacement. A constant head, liquid seal device ensures that the gas pressure in the reactor is maintained at a constant value throughout the test run. The collected gas can be exhausted from the vessel and the volume re-filled with water during a run without breaking the liquid seal.
Liquid and gas sampling points are located at all strategic points around the reactors. Non-return valves and liquid seal syphon breaks are included in the process pipework to ensure each reactor operates at a constant volume without the ingress of air or the danger of accidental syphonic action.
The equipment is mounted on a vacuum formed plastic base with an integral drain channel to cope with spillages and wash down.
Reactors:
Two, indentical -nominal capacity:
5 litres packed volume:
4 litres 150mm dia x 250mm high
Reactor packing: 25mm diameter Bio-balls
Temperture control: For each reactor: 200W heating jacket with PID control
from a temperature sensor positioned inside the reactor.
Set point within range ambient to 55°C, the jacket is thermostatically
protected by a cut-out set at 85°C.
Feed pumps: Two, identical peristaltic pumps - variable speed using 10
turn potentiometer to 4rpm supplied with three tube diameters:
1.6, 3.2 and 4.0mm, flow rates from 0.2 to 5.8 l/day
Gas collection vessels:Two, identical - linear scale, 0-5 litre capacity
Broadly speaking the anaerobic process may be divided into two distinct stages, (1) the hydrolysis of large molecular species into acetic acid and (2) the conversion of the acetic acid into methane and carbon dioxide.
This two stage process can be demonstrated by operating the two reactors in series, one to produce volatile acids from the initial substrate - acidogenesis and the second to convert the volatile acids into methane and carbon dioxide - methanogenesis. In addition the following basic differencies of the two stages of the process can be demonstrated:
(a) the low level of methanogenic activity during acidogenesis compared to methanogenesis
(b) the low level of COD removal exhibited by the acidogenic stage compared with the methanogenic stage.
Typical test results are shown below:
| a) Test conditions | ||
| ITEM | REACTOR 1 | REACTOR 2 |
|---|---|---|
| Temperature | 35°C - 37°C | 35°C - 37°C |
| Feed | Prepared glucose substrate with appropriate nutrients |
Effluent from reactor 1 |
| Feed rate | 2.5 - 3.5 l/day | 1 - 1.5 l/day |
| Feed pH | Corrected to 6.0 with HCl |
Without pH correction |
| b) Expected performance | ||
| ITEM | REACTOR 1 | REACTOR 2 |
|---|---|---|
| FEED: | ||
| COD | 7500-8500 mg/l | 5000-6000 mg/l |
| S.S* | very low | 100-500 mg/l |
| Alkalinity | 1000-1500 mg/l | 1000-2000 mg/l |
| TVA** | very low | 5000-6000 mg/l |
| pH | 6.5-7.0 | 4.5-6.0 |
| EFFLUENT: | ||
| COD | 5000-6000 mg/l | 500-600 mg/l |
| S.S* | 100-500 mg/l |
50-200 mg/l |
| Alkalinity | 1000-2000 mg/l | 2000-3000 mg/l |
| TVA** | 5000-6000 mg/l | 50-100 mg/l |
| pH | 4.5-6.0 | 6.8-7.3 |
| BIOGAS: | ||
| CH4 | 10-30% | 65-85% |
| CO2 | 70-60% |
15-35% |
| COD | ||
| REMOVAL: | 20-30% | 80-90% |
| GAS YEILD: | 0.5 l/g COD applied |
0.35 l/g COD applied |
| S.S* Suspended solids TVA** Total volatile acids |
||
Plastic feed and product tanks typically 30-50 litres, floor standing.
PH meter.
Analytical equipment as exists in most Water Quality Laboratories.
For measurement of pH, BOD, COD, alkalinity, total volatile acids and suspended
solids.
W5-A: 220-240V/1ph/50Hz
W5-B: 120V/1ph/60Hz
W5-G: 220V/1ph/60Hz
Volume 1.0m3
Gross weight: 150kg
Height: 0.76m
Width: 1.0m
Depth: 0.5m
|
![]() |
|---|